1. controls – Hobart Welding Products CYBERTIG 350LX User Manual
Page 23
OM-356 Page 19
SECTION 4 – OPERATION
4-1.
Controls
A. For 200/230/460 Volts And Non CE Units
Ref. ST-183 200-A / Ref. ST-183 260-A / Ref. ST-801 972
18
.
Top row of lights in upper left corner are
On for SMAW. Bottom row are On for
GTAW.
1
Process Control
See Section 4-3.
2
Current Control
See Section 4-4.
3
Output Control
See Section 4-5.
4
Start Mode Button
See Section 4-6.
5
Voltmeter
See Section 4-7
6
Ammeter
See Section 4-7
7
Amperage Adjustment
Control
See Section 4-8.
8
Output Selector Switch
See Section 4-2.
9
Power Switch Push Buttons
Use buttons to turn unit Off and On.
10 Postflow Time Control
See Section 4-11.
11 Preflow Time Control
See Section 4-10.
12 Balance/DIG Control
See Section 4-9.
Pulse Controls:
13 Pulser On/Off Switch
See Section 4-12.
14 Background Amperage Control
See Section 4-12.
15 Pulses Frequency Control
See Section 4-12.
16 Peak Time Control
See Section 4-12.
17 Sequence Controls (Optional)
See Section 4-14.
18 High Frequency Control
See Section 4-13.
8
1
2
3
4
5
6
7
13
14
15
16
10
11
12
17
9