12. electrical service guide – Hobart Welding Products IRONMAN OM-198 683C User Manual

Page 18

Advertising
background image

OM-198 683 Page 14

2-12. Electrical Service Guide

Input Voltage

200

230

400

460

575

Input Amperes At Rated Output

48

42

24

21

17

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Circuit Breaker

1

, Time-Delay

2

60

50

30

25

20

Normal Operating

3

70

60

35

30

25

Min Input Conductor Size In AWG/Kcmil

8

8

12

12

14

Max Recommended Input Conductor Length In Feet (Meters)

96

(29)

127

(39)

156

(47)

206

(63)

209

(64)

Min Grounding Conductor Size In AWG/Kcmil

8

10

12

12

14

Reference: 1999 National Electrical Code (NEC)

1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.

2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and

above).

Y

Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.

2-13. Selecting A Location And Connecting Input Power

1

Rating Label

Supply correct input power.

2

Plug (NEMA Type 6-50P)

3

Receptacle
(NEMA Type 6-50R)

Connect plug to receptacle.

4

Input And Grounding
Conductors

Connect directly to line disconnect
device if hard wiring is required.

5

Line Disconnect Device

See Section 2-12.

Y

Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

802 477

L1

L2

230 VAC, 1

18 in (457 mm) of
space for airflow

L1

L2

Y

Do not move or operate unit
where it could tip.

Y

Always connect
grounding conductor first.

= GND/PE

3

2

5

1

4

Advertising