SECTION 4 – MAINTENANCE &TROUBLESHOOTING
4-1.
Routine Maintenance
Y
Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
3 Months
Replace unreadable labels
Repair or replace
cracked weld cable
Clean and tighten weld terminals
6 Months
Blow out or vacuum inside.
OR
Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.
4-2.
Circuit Breaker CB1
1
Circuit Breaker CB1
If CB1 opens, wire feeding stops.
2
Circuit Breaker CB2
Overcurrent at pin D of receptacle
RC7 will cause CB2 to open.
3
Welding Gun
Check gun liner for blockage or
kinks.
4
Wire Drive Assembly
Check for jammed wire, binding
drive gear or misaligned drive rolls.
Allow cooling period and reset
breaker. Close door.
3
802 475-A / Ref. 800 797-C
4
1
2
4-3.
Unit Overload
Thermostat TP1 in rectifier Z1 protects the unit from damage due to overheating. If TP1 opens, wait several minutes
before trying to weld.