SECTION 4 – MAINTENANCE &TROUBLESHOOTING

4-1.

Routine Maintenance

Y

Disconnect power
before maintaining.

.

Maintain more often
during severe conditions.

3 Months

Replace unreadable labels

Repair or replace
cracked weld cable

Clean and tighten weld terminals

6 Months

Blow out or vacuum inside.

OR

Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.

4-2.

Circuit Breaker CB1

1

Circuit Breaker CB1

If CB1 opens, wire feeding stops.

2

Circuit Breaker CB2

Overcurrent at pin D of receptacle
RC7 will cause CB2 to open.

3

Welding Gun

Check gun liner for blockage or
kinks.

4

Wire Drive Assembly

Check for jammed wire, binding
drive gear or misaligned drive rolls.

Allow cooling period and reset
breaker. Close door.

3

802 475-A / Ref. 800 797-C

4

1

2

4-3.

Unit Overload

Thermostat TP1 in rectifier Z1 protects the unit from damage due to overheating. If TP1 opens, wait several minutes
before trying to weld.