Monitoring, Reporting, Notifications, and the Event Log

Data Protector Notifications

Chapter 7

350

Windows NT

To configure Windows NT SNMP traps, proceed as follows:

1. On the Cell Manager, open

Control Panel

,

Network

,

Services

. If

there is no SNMP Service entry in the list of network services under
the Services tab, perform step 2. If there is, skip step 2.

2. Click

Add

and select

SNMP Service

. Click

OK

. Insert the Windows

NT installation CD, or provide an alternative path to the requested
files. Click

Continue

.

3. Select

SNMP Service

and click

Properties

. Select the

Traps

tab

and enter

public

in the

Community Name

drop-down list. Click

Add

next to the

Community Name

drop-down list.

4. Click

Add

under

Trap Destinations

text box and enter the

hostname of the VPO Management Server. Click

Add

. Repeat this

step to add any number of VPO Management Servers.

5. Click

OK

. Click

Close

.

6. Start

omnisnmp

.

Windows
2000/XP/Server
2003

To configure Windows 2000/XP/Server 2003 SNMP traps, proceed as
follows:

1. On the Cell Manager, open

Settings

,

Network and Dial-up

Connections

.

2. In the

Advanced

menu, select

Optional Networking Components

to start the wizard.

3. In the wizard, select

Management and Monitoring

tools and click

Next

.

4. Follow the wizard to install the

Management

and

Monitoring

tools.

5. Open

Control Panel

,

Administrative Tools

,

Services

.

6. Right-click

SNMP Service

and select

Properties

.

a. Select the

Traps

tab and enter

public

in the

Community name

text box and the hostname of the VPO Management Server in the

Trap Destinations

text box.

b. Select the

Security

tab. Under

Accepted community names

,

select the community

public

, click

Edit

and set

Community

rights

to

READ CREATE

.

c. Confirm your settings.