Integrations with Other Applications

Data Source Integration (DSI)

Chapter 13

645

First select which data you want to log. Data Protector provides a
reporting command

omnirpt

located in the

/opt/omni/bin/

directory. This command can be used to gather various information
about the Data Protector environment. See the

omnirpt

manpage for

more information on the command. Secondly, write a script that in an
infinite loop queries for the selected data and writes it to standard
output.

2. Create the class specification file.

The class specification file defines what data you want to log and how
you want it to be logged. Data Protector provides a sample class
specification file

obdsi.spec

in the

/etc/opt/omni/dsi

directory.

Refer to the DSI manual for the complete syntax of the class
specification file.

3. Compile the class specification file.

Use the

sdlcomp

command from the

/opt/perf/bin

directory to

compile the class specification file. In order to compile the Data
Protector sample class specification file, use:

sdlcomp obdsi.spec OmniBack.log OmniBack

4. Configure

perflbd.rc

Before you start modifying

perflbd.rc

file, you have to stop the

mwa services. You do this using the following command:

/opt/perf/bin/mwa stop

Now you can edit the file

/var/opt/perf/perflbd.rc

. If you are

configuring Data Protector sample metrics, add the following line to
the file. Note that this has to be added as a single line:

DATASOURCE=OMNIBACKII

LOGFILE=/etc/opt/omni/dsi/OmniBack.log

5. Start the logging process.

Start the script that collects your data and pipe its output using

dsilog

command. In case of Data Protector sample metrics, use the

following command (in one line):

obdsi.ksh | /opt/perf/bin/dsilog OmniBack.log OMNIBACKII