Section 3, Camera control – Fairchild CAM/CMOS-2K.LS User Manual

Page 14

Advertising
background image

SECTION 3

Camera Control

3.1 Quick Start with the Camera Link

TM

Interface

Follow your Frame Grabber manufacturer’s instructions when inserting the frame grabber card into
your PC. Be sure that you install the correct configuration software that matches the camera that
you are using.

At this point your camera should already be connected to the DC power supply, and connected to
the frame grabber in your PC. Your frame grabber will see our camera and start communicating
almost immediately. As soon as your camera starts communicating with the frame grabber, you
can verify this fact by looking at your monitor and observing the video signal.

To communicate with your camera we have created specific commands. In the next section we will
go over these commands in detail.

3.2 Commands

Note: Commands are not case sensitive. To input commands, type in the three character
command and hit enter.

Command Syntax:

Command + enter, example: Type in RSH, then enter

Command + enter + value, example: Type in SSM then enter, then type 2

Command + enter + value + enter, example: Type in SLR then enter, then type 2000, then enter

RSH

This command allows you to perform a hard camera reboot.

The camera returns….………..…Reboot Started

RSS

This command allows you to perform a logic reset.

No return………………………….no message

INQ

This command will show you what camera is connected to your PC.

The camera returns…..………….Fairchild Imaging 2K CMOS

Fairchild Imaging • CAM/CMOS-2K.LS Line Scan Camera User’s Manual • Rev C• 14 of 42