Table 1.2.2

Settings and Controls

Function Factory

Calibrated

User

Settable

Camera

Link

Reset to Default Conditions

X

X

Fixed Pattern Noise Correction

X

X

X

PRNU Correction

X

X

Integration Time

X

X

External Synch / Free Run

X

X

Pixel Level Gain

X

X

Line Synchronization

X

X

Test

Patterns

X X X

1.3 Thermal Considerations

The CAM/CMOS 2K.LS has been carefully designed to separate the camera electronics
from the image sensor. In addition, the Fairchild Imaging CMOS sensor runs cooler than a
CCD device

.

Fairchild Imaging advises waiting until the camera has stabilized

thermally before performing offset and gain corrections. You can determine
that the camera has stabilized thermally by repeatedly using the "TSB"
command to read sensor temperature. When sensor temperature changes
less than 0.1

°

C per minute, the camera has stabilized.

Try to avoid excess temperatures in the ambient around the camera.