Interconnecting smoke alarms, Red and green led indicators – Firex I240C User Manual

Page 4

Advertising
background image

NOTE:

If this will be a single-station smoke alarm, cover orange wire with
electrical tape and tuck into ceiling, wall, or pattress.

Steps 6-9 for Models I240C, PAD240 and PADC240 ONLY:

6. Lift open battery pocket door.

7.

Connect new 9-volt battery to battery connector inside battery pocket. BE
SURE BATTERY IS SECURELY CONNECTED. Smoke alarm may beep
briefly when battery is installed.

8. Close battery pocket door, snapping it into place.

9. Push button and hold button on front cover of smoke alarm for three

(3) seconds. Smoke alarm should sound its alarm horn if battery is fit-
ted correctly.

10. Attach connector plug to pins on back of smoke alarm. Plug will only

fit one way and will snap into place.

11. Gently tug connector to be sure it is attached securely.

12. Position smoke alarm to mounting plate so that keyslot on side of

smoke alarm is to left of tab on mounting plate. Turn clockwise to lock
into

place.

NOTE: (For Models I240C, PAD240 and PADC240 only):

Smoke alarm will not mount to plate if battery is not installed.

13. Turn on power at main fuse box or circuit breaker. The green LED on the

cover should be illuminated.

14. Test smoke alarm. See “TESTING THE SMOKE ALARM”.

INTERCONNECTING

SMOKE ALARMS

Use 1.5mm

2

minimum solid or stranded wire with a rating of 230V. When

interconnecting, maximum wire length between any two is 450 m for
1.5mm

2

or 1200 m for 2.5mm

2

(20 OHMS loop resistance).

This smoke alarm may be interconnected with as many as 35 other
Models GC240, I240C, PG240, PAD240, PADC240, IAR230C, and
PAR230 smoke alarms. DO NOT connect to any other type or model
smoke alarm.

Connect smoke alarms to a single AC branch circuit. If local codes do
not permit, be sure the neutral wire is common to both phases.
Wiring must conform to IEE Regulations for electrical installation.

RED AND GREEN LED

INDICATORS

This smoke alarm features red and green LED indicators that can be seen
through the Push-to-Test button or the LED lens above the test button.
The LEDs indicate the following:

GREEN LED
ON

AC power is present

.

OFF

AC power is not present.

RED LED

Blinks once a minute

— indicating normal operation.

Blinks once a second

— smoke alarm senses smoke and simul-

taneously sounds an audible alarm.

Blinks once every 10 seconds

— smoke alarm is quieting an unwanted

alarm. (Models GC240, I240C,
PADC240, and IAR230C, PG240, PAR230.)

(Interconnected system only):

OFF

another smoke alarm in the network has sensed
smoke and is signalling this alarm.

4

BLUE

ORANGE

BROWN

LINE

INTERLINK

NEUTRAL

CEILING

ELECTRICAL BOX OR PATTRESS

BLUE

BLUE

ORANGE

BROWN

LINE

NEUTRAL

INTERLINK

CEILING

ELECTRICAL BOX OR PATTRESS

MODELS GC240, I240C,
PG240, PAD240, PADC240

MODELS IAR230, PAR230,

IAR230C

BLACK OR BLUE

ORANGE

ORANGE

RED OR BROWN

FOR INTERCONNECT: USE STANDARD 1.5MM

2

CABLE

NEUTRAL

LINE