On the meter status display, not only you can see the cur-

rent status of the metering, but also you can set param-

eters. The following shows the default setting when the

unit is shipped.

(1) Peak meter ON/OFF

You can enable or disable the peak meter function for the left and right

channels independently.

(2) VU meter reference (0 VU) level

You can set the reference level for the left and right channels indepen-

dently.

(3) Threshold level of the peak over indicator

You can set the peak threshold level for the left and right channels

independently.

(4) Internal battery type

You can set the battery type between alkaline or nickel hydride.

Parameter setting procedure

(1)

While the meter status display is shown, press the

[EDIT] key long enough.

The peak meter on/off setting of the left channel (“

”)

starts flashing. You can now edit the peak meter on/off

setting of the left channel.

(2)

While any parameter is flashing, press the [EDIT]

key to select the flashing parameter.

Pressing the [EDIT] key selects the flashing parameter

in the following order.

Peak meter on/off

The meter display shows both VU and peak metering (de-

fault).

The meter display shows only VU metering. The peak me-

tering is not shown.

VU meter reference level

The default value is “0 dB”. You can select between “0 dB”

and “+7 dB” in 1 dB steps.

<Memo>: It is recommended to change the reference level

appropriately when an external audio device connected to the

outputs of the unit has enough headroom. Normally, set it to “0”.

<Memo>: If you set the reference level other than “0”, “+” is lit

beside the “0” position of the VU meter, showing that the 0 VU

level is not the reference level.

+

+

Stereo VU meter

Left channel VU meter

Lch “PK”

In the following display example, both the left and right

peak meters are set to “

”.

See “Parameter details” below for the available options

of each parameter.

(4)

After editing parameters, press the [EDIT] key long

enough to stop flashing.

(5)

Press the [EDIT] key to exit the status display mode.

<Memo>: By bringing up the meter status display

while the unit is receiving a signal, you can edit pa-

rameters while checking movement of the VU and

peak meters.

(3)

While the desired parameter to be edited is

flashing, you can select a desired value using the

[+] or [-] key.

Meter status display

Parameter details

Lch “0VU”

Lch “OVR”

Rch “PK”

Rch “0VU”

Rch “OVR”

BAT TYPE

<Example>: If you set the reference level to “+5”,

the level at 0 VU is +5 dB higher than the refer-

ence level.

Flashing