Preparation of monitoring, Master fader reference setting, Input setting – Fostex FM-3 User Manual

Page 8

Advertising
background image

Preparation of monitoring

(1)

Connect headphones to the 1/4-inch [PHONES] jack

on the front panel or the mini-phone [PHONES] jack

on the right side panel.

You can use both the 1/4-inch and mini-phone jacks

simultaneously.

(2)

Set the monitor select switch to “ST” and adjust the

monitor level using the [PHONE] control.

Master fader reference setting

(1)

Turn down the rotary faders on input channels 1

through 3.

(2)

Set the [SLATE] switch on the front panel to “1k”

(upper position).

(3)

Set the [MASTER] L and R faders to the two-o’clock

position (marked in orange) so that the meter

needles point to 0 VU (see the figure below).

Normally this is the reference output position.

(4)

After adjusting the reference level, switch the [SLATE]

switch to “OFF”.

Input setting

(1)

Set the [MASTER] faders to the reference position.

(2)

Receive input signals and adjust the trim control of

each channel.

Adjust the trim control appropriately so that the peak

indicator does not light in red at the maximum sound level.

(3)

Raise up the channel fader of each channel

gradually until the meter shows the proper level.

(4)

Set the pan and [HPF] switches of each channel if

required.

It is recommended to cut the unnecessary low frequency

range using the [HPF] switch when you use a microphone.

(5)

If you want to apply the limiter to the main output, set

the [LIMITER] switch to “ON” (or “LINK”).

<Memo>: In the following figures, the meter nee-

dles point the reference (0 VU).

Stereo metering

Mono metering

8

Advertising