Model f80a, Important, Danger – Fedders F80A User Manual

Page 6: Table 2: clearances to combustibles

Advertising
background image

5

MODEL F80A

DIMENSIONS (Inche

MODEL

WIDTH

DEPTH

HEIGHT

SUPPLY

A

35-2

14-1/2

29

35

13-1/2 x 19

50-3

14-1/2

29

35

13-1/2 x 19

70-3

16

29

35

15 x 19

70-4

17-1/2

29

35

16-1/2 x 19

85-3

17-1/2

29

35

16-1/2 x 19

85-4

4

100-

20-1/2

29

35

19-1/2 x 19

100-5

20-1/2

29

35

19-1/2 x 19

115-5

22

29

35

21 x 19

MODEL

RETURN

S

35-2

14 x 22

13-1/2 x 22

1/2

3

1

50-3

14 x 22

13-1/2 x 22

1/2

3

1

70-3

14 x 22

14-1/2 x 22

3/4

4

70-4

14 x 22

2

85-3

14 x 22

14-1/2 x 22

1-1/2

4

85-4

4

100-

14 x 22

16 x 22

2-1/4

4

100-5

14 x 22

2

115-5

14 x 22

2

1

Vent outlet 4”

-

2

Two return air openings required

G

A

H

C

G

B

F

E

D

J

L

L

K

DIMENSIONS (Inches)

MODEL

WIDTH

DEPTH

HEIGHT

SUPPLY

AB

C

F x G

35-2

14-1/2

29

35

13-1/2 x 19

50-3
70-3

16

29

35

15 x 19

70-4

17-1/2

29

35

16-1/2 x 19

85-3
85-4

4

20-1/2

29

35

19-1/2 x 19

100-

3

100-

100-5

20-1/2

29

35

19-1/2 x 19

115-5

22

29

35

21 x 19

135-5

22

29

35

21 x 19

135-5

MODEL

RETURN

SIDE

BOTTOM

VENT

D x E

J x K

L

H

35-2

14 x 22

13-1/2 x 22

1/2

3

1

50-3
70-3

14 x 22

14-1/2 x 22

3/4

4

70-4

14 x 22

2

14-1/2 x 22

1-1/2

4

85-3

14 x 22

14-1/2 x 22

1-1/2

4

85-4

4

14 x 22

16 x 22

2-1/4

4

100-

3

100-

100-5

14 x 22

2

16 x 22

2-1/4

4

115-5

14 x 22

2

19 x 22

1-1/2

5

1

14 x 22

2

19 x 22

1-1/2

5

1

1

Vent outlet 4”

- Use reducer fittings.

2

Two return air openings required

FIGURE 2: DIMENSIONS

TABLE 3: DIMENSIONS

CLEARANCES

Table 2 (below) provides the certified clearances to
combustibles.

IMPORTANT:

This furnace requires a minimum of 24-inches of front
clearance for service purposes. For this purpose, service
clearance takes precedence over clearance to combustibles.

DANGER

COMBUSTIBLE MATERIAL MUST NOT BE PLACED ON OR
AGAINST THE FURNACE JACKET.

THE AREA AROUND THE FURNACE MUST BE KEPT CLEAR
AND FREE OF ALL COMBUSTIBLE MATERIALS INCLUDING
GASOLINE AND OTHER FLAMMABLE VAPORS AND
LIQUIDS.

PLACEMENT OF COMBUSTIBLE MATERIALS ON, AGAINST
OR AROUND THE FURNACE JACKET CAN CAUSE AN
EXPLOSION OR FIRE RESULTING IN PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.

THE HOMEOWNER SHOULD BE CAUTIONED THAT THE
FURNACE AREA MUST NOT BE USED AS A BROOM
CLOSET OR FOR ANY OTHER STORAGE PURPOSE.

UPFLOW FURNACES ARE DESIGN CERTIFIED FOR
INSTALLATION ON COMBUSTIBLE FLOORS. THIS SHALL
BE INTERPRETED AS A WOOD FLOOR ONLY.

THE FURNACE MUST NOT BE INSTALLED DIRECTLY ON
CARPETING, VINYL TILE, OR OTHER COMBUSTIBLE
MATERIAL EXCEPT WOOD. INSTALLATION ON
COMBUSTIBLE MATERIAL CAN RESULT IN FIRE, CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

UPFLOW

COUNTERFLOW

HORIZONTAL

1"

0"

2"

1"

1"

2.5"

.5"

.5"

.5"

3.5"*

3.5"*

3.5"*

0"

0"

0"

0"

0"

1"**

0"***

0"****

0"

6"

6"

6"

1"

1"

1"

CLOSET
CABINET

CLOSET
CABINET

CLOSET
CABINET

UNIT TOP

PLENUM
TOP/BOTTOM

PLENUM SIDES

UNIT FRONT

UNIT BACK

UNIT SIDES

ENCLOSURE

UNIT BASE

FLUE
PIPE

C VENT
B VENT

TABLE 2: CLEARANCES TO COMBUSTIBLES

*

24 inches required for service

** Supply air end 1 inch / return air end 0 inches

*** Certified for closet installation on combustible flooring

**** Certified for installation on combustible flooring

only when installed on special base (part # 30476).

See the appliance rating plate affixed to the furnace
for specific model number, serial number and
clearance to combustibles information.