Installation – FMI BV42(B) User Manual

Page 10

Advertising
background image

www.fmiproducts.com

123492-01F

10

WARNING: do not allow any

combustible materials to overlap

the firebox front facing.

IMPORTANT: Noncombustible materials such
as brick, tile, etc. may overlap the front facing,
but should never cover any necessary open-
ings like louvered slots.

WARNING: do not allow

noncombustible materials to

cover any necessary openings

like louvered slots.

WARNING: use only non-

combustible mortar or adhe-

sives when overlapping the front

facing with noncombustible

facing material.

INSTALLATION

Continued

Figure 7 - Attaching Firebox to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

Figure 8 - Installing Gas Line and

Equipment Shutoff Valve (Model May

Vary From Illustration)

Knockout
Locations
(Knock Out
One Hole)

Gas Line Hole

Equipment Shutoff
Valves (Install One)

INstAllING FIRebox usING
optIoNAl AccessoRy mANtels

warninG: a qualified ser-

vice person must install firebox.

follow all local codes.

This firebox may be installed using a cabinet
mantel accessory against a wall in your
home. The firebox and cabinet mantel can
be installed directly on the floor. A trim kit is
included with the mantel accessories. Follow
instructions with mantel for installation.

INstAllING GAs lINe

notiCe: a qualified service per-

son must connect heater to gas

supply. follow all local codes.

IMPORTANT: See Connecting to Gas Supply
in your log set owner’s manual for details on
gas hookup.
You may run the gas line from either side of
the firebox (see Figure 9). Decide which side
you want to run the gas line from.
Note: This is one option for installing shutoff
valve. Check local codes for equipment shut-
off valve location requirements.