IMPORTANT: Vent-free gas log heaters add
moisture to the air. Although this is beneficial,
installing firebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation
, page 5.
IMPORTANT: Make sure firebox is level. If fire-
box is not level, log set will not work properly.
Note: Your firebox is designed to be used in zero
clearance installations. Wall or framing material can
be placed against any exterior surface on the rear,
sides, top or bottom of your firebox, except where
standoff spacers are integrally attached. If standoff
spacers are attached to your firebox, these spac-
ers can be placed directly against wall or framing
materials. Use the dimensions shown for rough
opening to create the easiest installation.
Use dimensions shown for rough openings
to create the easiest installation (see Built-In
Firebox Installation
, page 9).

INstAllAtIoN cleARANces

WARNING: maintain the

minimum clearances. if you can,

provide greater clearances from

floor, ceiling and adjoining wall.

Carefully follow these instructions. This will
ensure safe installation.
Minimum wall and Ceiling Clearances (see
figure 4)
A. Clearances from the side of fireplace

cabinet to any combustible material and
wall should follow diagram in Figure 4.

Example: The face of a mantel, bookshelf,
etc. is made of combustible material and
protrudes 3

1

/

2

" from the wall. This com-

bustible material must be 4" from the side
of the fireplace cabinet (see Figure 4).

B. Clearances from the top of firebox opening

to ceiling should not be less than 42".

C. When firebox is installed on carpeting or

other combustible material, other than
wood flooring, firebox should be installed
on a metal or wood panel extending the
full width and depth of enclosure.

D. Clearances from bottom of firebox to the

floor is 0".

These fireboxes can be installed as freestanding
units against a wall with the approved, optional
cabinet mantels (s

ee Accessories, page 14

) or as

a built-in unit. Clearances are the same for either
installation method.

INSTALLATION

Continued

Figure 4 - Minimum Clearance for

Combustible to Wall

*Minimum 16" from Side Wall

*

Caution: Do not install fire-

box directly on carpet or vinyl.

Example

mantel clearances for built-In Installation
If placing custom mantel above built-in firebox,
you must meet the minimum allowable clear-
ance between mantel shelf and top of firebox
opening shown in Figure 5, page 9. These are
the minimum allowable mantel clearances for
a safe installation. Use larger clearances wher-
ever possible to minimize the heating of objects
and materials placed on the mantel.

cAutIoN: do not allow

the vent-free gas log heater

to touch or extend beyond the

fireplace screen.

notiCe: surface temperatures

of adjacent walls and mantels be-

come hot during operation. walls

and mantels above the firebox

may become hot to the touch.

if installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NotIce: If your installation does

not meet the minimum clearances

shown, you must do one of the

following:

• raise the mantel to an accept-

able height

• remove the mantel