2.6 Changing AC Power Specification

To change AC power specification from 100 VAC to 220 VAC and vice versa, change fuse and
jumper wire settings and adjust the overvoltage detection circuit, following the instructions in this
section.

Processor unit

Add or remove jumper connector P108 from the PWR board 03P9339 and change the fuse in the
processor unit according to ship's mains. Then, adjust the overvoltage detection circuit, the pro-
cedure for which is shown on the next page.

Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring
to the illustration on the next page. (VH8 connector housing is to be plugged into J108.)

Processor unit, inside view

Power supply

Fuse

Jumper connector P108

100 VAC

10A

Necessary

220 VAC

5A

Unnecessary

Cover of PWR board

Fuse

Upper part of processor unit
(SPU assembly omitted)

PWR board

TB1