Troubleshooting, En-14 – Friedrich P/N9368987060-01 User Manual

Page 15

Advertising
background image

En-14

TROUBLESHOOTING

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Smells:

Mist or steam are
emitted:

Air flow is stopped:

Problem

● If the unit is stopped and then immediately started again, the com-

pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

● Whenever the electrical breaker is turned off then on again, the

protection circuit will operate for about 3 minutes, preventing unit
operation during that period.

● During operation and immediately after stopping the unit, the

sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

● During operation, a slight squeaking sound may be heard. This is

the result of minute expansion and contraction of the panel due
to temperature changes.

● During Heating operation, a sizzling sound may be heard occa-

sionally. This sound is produced by the Automatic Defrosting op-
eration.

● Some smell may be emitted from the indoor unit. This smell is

the result of room smells (furniture, tobacco, etc.) which have
been taken into the air conditioner.

● During Cooling, a thin mist may be seen emitted from the indoor unit.

This results from the sudden Cooling of room air by the air emitted
from the air conditioner, resulting in condensation and misting.

● During Heating operation, the outdoor unit’s fan may stop, and

steam may be seen rising from the unit. This is due to the Auto-
matic Defrosting operation.

● When Heating operation is started, fan speed is temporarily very

low, to allow internal parts to warm up.

● During Heating operation, if the room temperature rises above

the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat to a higher setting.

● During Heating operation, the unit will temporarily stop opera-

tion (between 2 and 16 minutes) as the Automatic Defrosting mode
operates. During the Automatic Defrosting operation,

will

be shown on the remote controller display.

● The fan may operate at very low speed when the unit is monitor-

ing the room’s temperature.

● In the monitor AUTO operation, the fan will operate at very low speed.

● In case of Multi-type unit, if multiple units are operated in

different operation modes as shown below, the units operated
afterward will stop and

will be shown on the remote

controller display of the stopped indoor units.
Heating mode and cooling mode (or dry mode)
Heating mode and fan mode

See Page

9

9

9

NORMAL

FUNCTION

Instructions relating to heating are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

WARNING!

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker,
and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

10

9368987060-01_OM_en.p65

2/4/10, 4:46 PM

14

Advertising