OWNER’S MANUAL

LOCAL CODES

Install and use heater with care. Follow all
local codes. In the absence of local codes, use
the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*
.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT
FEATURES

OPERATION

This heater is clean burning. It requires no
outside venting. There is no heat loss out a
vent or up a chimney. Heat is generated by
realistic, dancing yellow flames. This heater
is designed for vent-free operation with flue
damper closed. It has been tested and ap-
proved to ANSI Z21.11.2 standard for
unvented heaters. State and local codes in
some areas prohibit the use of vent-free
heaters. This heater may also be operated as
a vented decorative (ANSI Z21.60) product
by opening the flue damper.

SAFETY PILOT

This heater has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
shuts off the heater if there is not enough
fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system
requires no matches, batteries, or other
sources to light heater.

UNPACKING

PRODUCT IDENTIFICATION

Figure 1 - Heat Majic™ Log Set

Base Assembly

Piezo Ignitor

Burner

One-Piece
Log Set

Control Knob

CAUTION: Do not remove the

data plates from the grate assem-
bly. The data plates contain impor-
tant product information.

1.

Remove logs and heater base assem-
bly from carton.

Note:

Do not pick up

heater base assembly by the burner.
This could damage heater. Always
handle base assembly by grate.

2.

Remove all protective packaging ap-
plied to logs and heater for shipment.

3.

Check all items for any shipping dam-
age. If damaged, promptly inform
dealer where you bought heater.

SAFETY
INFORMATION

Continued

12. This heater needs fresh, outside air ven-

tilation to run properly. This heater has
an oxygen depletion sensor (ODS) pi-
lot light safety system. The ODS shuts
down the heater if not enough fresh air
is available. See Air for Combustion
and Ventilation,
pages 4 through 6. If
heater keeps shutting off, see Trouble-
shooting,
pages 17 through 19.

13. Do not run heater

• where flammable liquids or vapors

are used or stored

• under dusty conditions

14. Do not use this heater to cook food or

burn paper or other objects.

15. Do not use heater if any part has been

exposed to or under water. Immediately
call a qualified service technician to in-
spect the room heater and to replace any
part of the control system and any gas
control which has been under water.

16. Do not operate heater if any log is bro-

ken. Do not operate heater if a log is
chipped (dime-sized or larger).

17. Turn heater off and let cool before ser-

vicing. Only a qualified service person
should service and repair heater.

18. Operating heater above elevations of

4,500 feet could cause pilot outage.

19. Provide adequate clearances around air

openings.