True-rms Remote Display Digital Multimeter

Safety Information

3

•

Remove the test leads from the Meter
before the battery door on the Meter
base is opened.

•

Examine the test leads for damaged
insulation or exposed metal. Measure the
test leads for continuity. Replace
damaged test leads before you use the
Meter.

•

Do not apply more than the rated
voltage, shown on the Meter, between
the terminals or between a terminal and
earth ground.

•

Do not operate the Meter with the battery
door removed or the case open.

•

Be careful around voltages >30 V ac rms,
42 V ac peak, or 60 V dc. These voltages
pose a shock hazard.

•

Use only the replacement fuse specified
by the manual.

•

Use the correct terminals, function, and
range for measurements.

•

Do not work alone.

•

For current measurements, connect the
Meter to the circuit after you remove
circuit power. Always put the Meter in
series with the circuit.

•

Connect the common test lead before
the live test lead and remove the live test
lead before the common test lead.

•

Do not use the Meter if it operates
incorrectly. Protection can be
compromised. If you are unsure, have
the Meter examined.

•

Do not use the Meter around explosive

gas, vapor or in damp or wet

environments.