APPENDIX A- WML-C AND MPL-B BURNER SET UP

WML-C AND MPL-B furnaces may be used with the following oil burners.

Please note: The Beckett AF, and Riello 40F oil burners are for applications using indoor air for combustion only. For sidewall
venting applications utilizing outdoor air for combustion, use the Beckett AFII or the Riello 40BF (Balanced Flue) oil burners
only.

Table A-1 Beckett AF Oil Burner Set-Up

Beckett AF Series Oil Burners

(For use with chimney vented units only)

Furnace

Model

Output

BTU/Hr

Burner

Model

Nozzle

Pump

Pressure

Flow Rate

Head

1

Static

Plate

WML-60C

2

58,000

AF76BNHS

0.50 / 80°A

100

PSIG

0.50

USGPH

F3 3-

⅜ in.

WML-80C

75,000

AF76BNHS

0.65 / 80°A

100

PSIG

0.65

USGPH

F3 3-

⅜ in.

WML-90C

85,600

AF76BNHS

0.75 / 80°A

100

PSIG

0.75

USGPH

F3 3-

⅜ in.

MPL-90B

85,500

AF76XN

0.75 / 80°A

100

PSIG

0.75

USGPH

F3

2- ¾ in.

MPL-100B

96,000

AF76XN

0.85 / 80°A

100

PSIG

0.85

USGPH

F3

2- ¾ in.

MPL-120B

112,000

AF76XN

1.00 / 60°A

100

PSIG

1.00

USGPH

F3

2- ¾ in.

MPL-130B

123,000

AF76YB

1.10 / 70°A

100

PSIG

1.10

USGPH

F6

2- ¾ in.

1

Head is shielded by ceramic insulator.

2

Low Firing Rate Baffle required when using a 0.50-gallon nozzle.

Table A-2 Beckett AFII Oil Burner Set-Up

Beckett AFII Series Oil Burners

(For use with sidewall vented units using outdoor combustion air)

Furnace

Model

Output

BTU/Hr

Burner

Model

Nozzle

Pump

Pressure

Flow Rate

Head

WML-60CB2

63,500

AFII-85

0.50 / 60°A

145

PSIG

0.55

USGPH

FB0

WML-80CB2

75,000

AFII-85

0.60 / 60°A

145

PSIG

0.65

USGPH

FB3

WML-90CB2

85,600

AFII-85

0.70 / 60°A

145

PSIG

0.75

USGPH

FB3

MPL-90BB2

85,500

AFII-150

0.70 / 60°A

145

PSIG

0.75

USGPH

FB0

MPL-100BB2

96,000

AFII-150

0.80 / 60°A

145

PSIG

0.85

USGPH

FB3

MPL-120BB2

112,000

AFII-150

0.85 / 70°A

145

PSIG

1.00

USGPH

FB3

Table A-3 Riello 40F Series Oil Burner Set-Up

Riello 40F Series Oil Burners

(For use with chimney vented units)

Furnace

Model

Output

BTU/Hr

Burner

Model

Nozzle

Pump

Pressure

Flow Rate

Air Gate

Turbulator

Setting

WML-60CRF

59,500

40F3

0.50 / 60°W

105

PSIG

0.51

USGPH

2.6

1.0

WML-80CRF

75,000

40F3

0.60 / 60°W

115

PSIG

0.65

USGPH

2.6

1.5

WML-90CRF

85,600

40F3

0.65 / 60°W

135

PSIG

0.75

USGPH

3.6

2.0

MPL-90BRF

85,500

40F5

0.60 / 60°W

145

PSIG

0.75

USGPH

2.25

0.0

MPL-100BRF

96,000

40F5

0.65 / 60°W

145

PSIG

0.85

USGPH

2.5

0.5

MPL-120BRF

112,000

40F5

0.85 / 60°W

145

PSIG

1.00

USGPH

2.75

1.0