SIMPLIFIED INSTALLATION INSTRUCTIONS

DETAILED INSTALLATION INSTRUCTIONS

1. Insulate the water reservoir. See figure 3.

2. Select the mounting location on the duct and tape

on the mounting template.

3. Drill the (8) 1/8" mountings holes.

4. Cut out the humidifier opening in the duct.

5. Insert the humidifier into the opening and screw in

place.

6. Flush and connect the water line.

7. Connect the drain line.

8. Make 24 VAC electrical connections to achieve fan

operation and interlock circuit.

9. Install and connect the humidistat.

10. Plug power cord into a grounded dedicated 120 VAC, 20

amp outlet for S2000 (240 VAC, 15 amp for S2020).

1. INSULATE WATER TANK RESERVOIR

2. LOCATION-LOCATION - Required Criteria

4. MOUNTING TEMPLATE

5. DRILL HOLES AND CUT OPENINGS

With insulation foil side down, remove adhesive backing.

Align humidifier so that front side of unit meets long edge of

insulation. Fold insulation up onto sides of humidifier and

press firmly. Apply 5 continuous strips from the tape

provided to seal the foil as shown. The tape will prevent the

sharp duct edges from damaging the foil. Use additional foil

tape to repair damage to the foil. The Insulation MUST be

applied to the tank regardless of the mounting location.

DO NOT INSTALL this unit in an attic period. Do Not

Install this unit in any area that may fall below 35

degrees F. Doing so will void your warranty!

The steam

humidifier can be installed in either the warm air supply or the

cold air return ducts; however the preferred location would be

in the warm air supply duct of the system. This humidifier does

not require warm air to evaporate the water in order to provide

humidity, but it will operate more efficiently in the warm air duct

and condensation is less likely to occur on the surrounding cold

surfaces. Efficiency is lost in a return air duct location.

When selecting a location on the duct, be certain that there is

enough room in the duct for the water reservoir. There should be

at least five (5) inches above the reservoir and the reservoir

should not occupy more than about 25 percent of the duct space.

If this criteria can not be met, you should install the unit under

the duct by means of the tank flange. See page 6.

If a suitable means of gravity draining the unit is not available

or cannot be provided, the unit will work with the drain valve

electrically disconnected. Call the Technical Support Hotline

for Instructions.

It is highly recommended but not required that the

use of Fiberglass duct-board with this product

includes an anti-microbial treatment.

Providing Adequate Structural Support for this unit is the

responsibility of the Installer. It is recommended to

reinforce the cut openings with folded lengths of sheet-

metal to provide rigidity to the duct opening. Now the

screws must pass through 3 layers of metal when inserted.

DO NOT install this unit into fiberglass duct without

adequate structural support! Both models weigh

approximately 9 lbs. empty and 15lbs. full of water.

Two mounting templates are provided. Choose the correct

template for your mounting method. Tape the mounting

template to the duct. The template must be leveled using the

top of the cutout on the template. The template should be

located so that the bottom of the reservoir cut-out is flush with

the inside of the bottom of the duct for horizontal duct. Since

most ducts are insulated this additional space, about one (1)

inch, must be accounted for when determining the location

for the bottom of the reservoir cut-out. If you are mounting it

under the duct, make sure the duct is level.

Use an electric drill, with grounded power cord, to drill eight

(8) mounting holes, 1/8" diameter, in the duct. These can be

drilled through the template at the locations indicated on the

template.

A saber saw or tin snips can be used to cut out the water

reservoir opening.

Insert and/or mount the Humidifier and secure it to the duct

with the provided screws.

2

FIG. 4

MOUNTING TEMPLATE

MODEL S2000 & S2020

1. TAPE TEMPLATE IN LEVEL POSITION.

2. DRILL (8) HOLES FOR SHEET METAL SCREWS

SHOWN ON TEMPLATE (DO NOT DRILL LARGER

THAN 1/8" DIAMETER.

3. CUT OUT SOLID LINE AREA AS MARKED.

4. MOUNT HUMIDIFIER PER INSTRUCTIONS.

CUT ON LINE

CUT ON LINE

C

U

T

O

N

L

IN

E

C

U

T O

N

L

IN

E

P/N 094021B0037

3. WEIGHT - Required Criteria

USE TAPE TO SEAL THE FOIL

TO THE FRONT MOUNTING PLATE

(3 PLACES-SIDES AND BOTTOM)

INSULATION

(FOIL SIDE OUT)

USE TAPE TO SEAL

THE OUTSIDE EDGE

OF THE FOIL

(2 PLACES)

FIG. 3