4 operating the filter – Frymaster STUFF 8195809 User Manual

Page 22

Advertising
background image

SUFF/UFF FILTRATION SYSTEMS

CHAPTER 3: INSTALLATION AND OPERATION

3-14

3.4 Operating the Filter


3.4.1 Pan Preparation and Operation

See Section 3.2.1, Assembling the Filter, and Section 3.2.2, Installing the Filter, for the appropriate
filter preparation procedure.

CAUTION

NEVER operate the filter unit unless cooking oil is

at operating temperature (~350°F/ ~177°C).


1. Ensure the filter pan assembly is prepared as described in Section 3.2.1, Assembling the Filter,

and turn fryer off.


2. Remove fry baskets from frypot and skim any

large debris from the oil. Use extreme
caution, as oil is at or near operating
temperature (~350°F/~177°C).











3. Remove the support grid from the frypot

using the clean-out rod. Stir the oil with the
frypot/filter brush to suspend debris prior to
draining.














Prior to filtering, skim any large debris from oil in
frypot.

Removing support grid from fry vessel prior to
filtering.

Advertising