Error messages

Error messages

This chapter contains error messages generated by the mainboard.

Available CPUs do not support the same bus frequency – System halted!
Memory type mixing detected
Non Fujitsu Siemens Memory Module detected – Warranty void
There are more than 32 RDRAM devices in the system

Check whether the system configuration has changed. If necessary, correct the settings.

BIOS update for installed CPU failed

This message appears if the microcode update required for the connected processor is not
contained in the system BIOS.

► Boot the system with the inserted Flash BIOS floppy disk.
► Abort the normal Flash BIOS update by answering the question about whether you want to

perform the update with

n

► To carry out the Flash BIOS update for the processor, enter:

flashbio

└┘

/p6

Check date and time settings

The system date and time are invalid. Set the current date and time in the Main menu of the
BIOS Setup.

CPU ID 0x failed

Switch the server off and on again. If the message is still displayed, go into the BIOS setup and

set the corresponding processor to Disabled in the Server - CPU Status menu; please contact

your sales outlet or customer service centre.

CPU mismatch detected

You have replaced the processor or changed the frequency setting. As a result, the
characteristic data of the processor have changed. Confirm this change by running the BIOS
Setup
and exiting it again.

Diskette drive A error
Diskette drive B error

Check the entry for the diskette drive in the Main menu of the BIOS Setup.

Check the connections to the diskette drive.