5.2 Error Indication

When the FS-1562 detects a fault in the synthesizer unit (frequency unlocked), the frequency or
channel number blinks.

5.3 Replacing Fuses

To protect the unit from overcurrent and equipment fault, two 20 A fuses for the transceiver unit
(and two 30 A fuses for the PA-2500) are provided in snap-in holders on the power cable and two
fuses in the PR-300 Power Supply Unit (for 150 W set).

Power Cable Fuse: 20 A (for both 150 W/250 W) and 30 A (for PA-2500 power amplifier unit)

Power supply unit (for 150 W sets)
Remove the fuse cover using a screwdriver (+), then replace:
Fuse

10 A for 100-120 VAC (5 A for 200-240 VAC)
20 A for 24 VDC

RED LIGHT

GREEN LIGHT

ON

OFF

100V 10A
220V 5A

ON

OFF

125V 20A

AC IN

DC IN

DC OUT

PR-300

L

N

G

+

-

+

-

+

-

24V

FUSE

AC POWER Switch

DC POWER Switch

FRONT PANEL OF PR-300

The Power Supply Unit PR-850A does not have a fuse on the front panel but a circuit breaker. If
this has been tripped off, remove the cause of tripping and turn it on (Upward position on the
front panel). A fuse (20 A) is provided in the power cable.

POWER

ON

ON

OFF

AC INPUT 50/60Hz

DC OUTPUT

BREAKER

POWER LAMP

TERMINAL COVER

FRONT PANEL OF PR-850A