7. ALARMS

7-3

7.2

XTE Alarm, Border Alarm

The XTE (cross-track error) alarm warns you when own ship is off its intended course.
The Border alarm alerts you when own ship is nearing an area which you do not want to
approach.

: Alarm range

Setting line

Own ship's position

Alarm
setting

: Alarm

Destination
waypoint

Own ship
position

Alarm
setting

Intended
course

XTE ALARM

BORDER ALARM

XTE alarm, border alarm concept

1. Press [MENU], [1], [1], [0], [0], [2], [2] to display the Alarm Set menu.
2. Press the [3] key to choose XTE or Border.
3. Press the [ENTER/SELECT] key.
4. Key in alarm range (0.001-9.999). (To cancel input, press the [CANCEL/CLEAR] key.)
5. Press the [ENTER/SELECT] key.
6. Press the [MENU] key to finish.

To disable the XTE alarm or Border alarm, choose Off at step 2 in the above procedure.