False alarm control, Interconnecting smoke alarms, Red and green led indicators – Firex FADC User Manual

Page 5

Advertising
background image

NOTE: If this will be a single-station smoke alarm, cover yellow

wire with electrical tape and tuck into junction box.

8. Lift open battery pocket door.

9. Connect new 9-volt battery to battery connector inside battery

pocket. BE SURE BATTERY IS
SECURELY CONNECTED. Smoke
alarm may beep briefly when bat-
tery is installed.

10. Close battery pocket door,

snapping it into place. (For tam-
per-resist, use long-nosed pliers
to remove thin plastic from
notch on smoke alarm edge.)

11. Attach connector plug to pins on

back of smoke alarm. Plug will
only fit one way and will snap
into place.

12. Gently tug connector to be

sure it is attached securely.

13. Position smoke alarm to

mounting plate and turn
clockwise to lock into
place. To engage tamper-resist feature, insert pin into notch
on edge of smoke alarm after alarm is properly positioned in
base. (See instruction #10.)

NOTE: Smoke alarm will not mount to plate if battery is not installed.

14. Turn on power at main fuse box or circuit breaker.

15. Test smoke alarm. See TESTING THE SMOKE ALARM.

INTERCONNECTING SMOKE ALARMS

• This smoke alarm may be interconnected with as many as 11

other Firex model FADC, AD and ADC smoke alarms, or as
many as 6 Firex model ADH heat alarms for a total of not more
than 18 interconnected devices. DO NOT connect to any other
type or model smoke alarm.

• Connect smoke alarms to a single AC branch circuit. If local

codes do not permit, be sure the neutral wire is common to both
phases.

RED AND GREEN LED INDICATORS

This smoke alarm features separate red and green LED indicators.
The LEDs indicate the following:
GREEN LED

CONSTANT ON

— AC power is present.

OFF

— AC power is not present.

RED LED

— Can be seen through the

Push-to-Test button.

Blinks once a minute

— Indicating presence of a work-

ing battery.

Blinks once a second

— Smoke alarm senses smoke

and simultaneously sounds
an audible alarm.

Blinks once every 10 seconds — Smoke alarm is quieting an

unwanted alarm (Model ADC
only).

(Interconnected system only):
OFF — Another smoke alarm in the network has sensed

smoke and is signalling this alarm.

FALSE ALARM CONTROL

Model ADC features a False Alarm Control that, when activated,
quiets unwanted alarms for up to 15 minutes.

To use the False Alarm Control:

Press and release the test button during an unwanted alarm. The
alarm should stop within ten seconds. This means the smoke
alarm is in False Alarm Control.

WHITE

WHITE

WHITE

YELLOW

YELLOW

BLACK

BLACK

BLACK

TO NEUTRAL

TO 120 VAC

Insert pin here

5

Remove thin plastic

from notch

110-628F English 11/8/06 11:07 AM Page 5