Friedrich CP14-18-24 CP24N30 User Manual

Page 13

Advertising
background image

13

Problem

Possible Cause

Action

Compressor

does not run

Low voltage

Check voltage at compressor. 115V & 230V units
will operate at 10% voltage variance

T-stat not set cold enough or inoperative

Set t-stat to coldest position. Test t-stat & replace if
inoperative

Compressor hums but cuts off on B10 overload

Hard start compressor. Direct test compressor. If
compressor starts, add starting components

Open or shorted compressor windings

Check for continuity & resistance

Open overload

Test overload protector & replace if inoperative

Open capacitor

Test capacitor & replace if inoperative

Inoperative system switch

Test for continuity in all positions. Replace if inop-
erative

Broken, loose or incorrect wiring

Refer to appropriate wiring diagrams to check wiring

Problem

Possible Cause

Action

Fan motor

does not run

Inoperative system switch

Test switch & replace if inoperative

Broken, loose or incorrect wiring

Refer to applicable wiring diagram

Open capacitor

Test capacitor & replace if inoperative

Fan speed switch open

Test switch & replace if inoperative

Inoperative fan motor

Test fan motor & replace if inoperative (be sure
internal overload has had time to reset)

Problem

Possible Cause

Action

Does not cool or

only cools slightly

Undersized unit

Refer to industry standard sizing chart

T-stat open or inoperative

Set to coldest position. Test t-stat & replace if neces-
sary

Dirty fi lter

Clean as recommended in Owner's Manual

Dirty or restricted condenser or evaporator coil

Use pressure wash or biodegradable cleaning agent
to clean

Poor air circulation

Adjust discharge louvers. Use high fan speed

Fresh air or exhaust air door open on applicable
models

Close doors. Instruct customer on use of this feature

Low capacity - undercharge

Check for leak & make repair

Compressor not pumping properly

Check amperage draw against nameplate. If not
conclusive, make pressure test

Cooling Only Room Air Conditioners: Troubleshooting Tips