Problem

Possible Cause

Action

Room temperature

uneven

(Heating cycle)

Heat anticipator (resistor) shorted (on applicable
models)

Disconnect power to unit. Remove resistor from t-
stat bulb block. Plus in unit & allow to operate. Feel
resistor for heat. If not heat, replace resistor

Wide differential - partial loss of t-stat bulb charge

Replace t-stat & check

Incorrect wiring

Refer to appropriate wiring diagram. Resistor is
energized during "ON" cycle of compressor or fan.

Problem

Possible Cause

Action

Unit will not defrost

Incorrect wiring

Refer to appropriate wiring diagram

Defrost control timer motor not advancing
(applicable models)

Check for voltage at "TM" & "TM1" on timer. If no
voltage, replace control

Defrost control out of calibration (applicable models)

If outside coil temperature is 25F or below, &
preselected time limit has elapsed, replace defrost
control

Defrost control contacts stuck

If contacts remain closed between terminals "2"
& "3" of the defrost control after preselected time
interval has passed, replace control

Defrost control bulb removed from or not making
good coil contact

Reinstall & be assured that good bulb to coil contact
is made

Problem

Possible Cause

Action

Does not heat

adequately

Exhaust or fresh air door open

Check if operating properly. Instruct customer on
proper use of control

Dirty fi lter

Clean as recommended in Owner's Manual

Unit undersized

Check heat rise across coil. If unit operates
effi ciently, check if insulation can be added to attic
or walls. If insulation is adequate, recommend
additional unit or larger one

Outdoor t-stat open (applicable models)

T-stat should close at 38°F. Check continuity of
control. If temperature is below 38°F, replace control

Heater hi-limit control cycling on & off

Check for adequate fan air across heater. Check
control for open at 160°F & close at 150°F

Shorted supplementary heater

Ohmmeter check, approx. 32-35 ohms

Incorrect wiring

Check applicable wiring diagram

Heat / Cool Room Air Conditioners: Troubleshooting Tips