Wiring, 1 wiring outline, Caution – Furuno Network Sounder DFF3 User Manual

Page 19

Advertising
background image

12

2.

WIRING

2.1

Wiring Outline

Connect the power cable, transducer cables, sensor cable, network cable and ground wire to their
respective locations on the network sounder. See the next page for how to connect the transducer
cables.

Ground

Connect a ground wire (IV-2 sq, local supply) between the
ground terminal and ship’s ground to prevent interference to
the sounder picture. Make the length of the wire as short as
possible. For FRP vessels, install a ground plate that mea-
sures about 20 cm by 30 cm on the outside of the hull bot-
tom and connect the ground wire there.

GROUND

MOD-Z072 Cable
- Standard: 5 m
- Option: 2 m, 10 m

DFF3

Ground wire
(IV-2 sq)

BATTERY

White

Black

Shield (green)

12 - 24 VDC

MJ-A3SPF0013-035C

(3.5 m)

High Freq.

Transducer

Low Freq.

Transducer

NavNet 3D
or HUB-101

NavNet
or HUB-100

MJ-A6SPF0017 cable
(1/5/10/20/30 m)

Temperature or

Speed/Temperature

Sensor

NETWORK

12-24VDC

2.8-1.4A

TEMP

H TRANSDUCER L

Ground the equipment
to prevent mutual
interference.

CAUTION

Advertising