CM6000

Install Guide

Alarm and Starter System

www.firstechonline.com | www.compustar.com

Copyright 2009 Firstech, LLC.

Page 14

Connector 2 (CN2), 2-Pin: Optional Battery Back-up

Pin 1 Red - Constant 12 V positive (+) input and (+) charging output.

Pin 2 Black - Ground (-) negative input.

Connector 3 (CN3), 20-Pin: Programmable Output Connector (POC)

IMPORTANT:

Odd Pin numbers 1 through 17 are programmable for up to 12 different output types. Refer to

Special Option Group 2 for complete details.

Pin 1 Blue - 250mA negative (-) output when armed and during remote start (while running). This wire is

pre-wired to the anti-grind/starter-kill relay. Caution: When this wire is being used to trigger aftermarket

accessories it must be diode isolated.

Pin 2 Orange/Black - Parking Light Reminder (-) input that monitors the vehicle’s parking lights. It prevents

the unit from setting Reservation Mode if this wire sees input.

Pin 3 Green/White [POC 1] - Parking light 250mA negative (-) output. The proper wire will test (-) when the

parking light switch is in the on position.

Pin 4 Light Blue – Parking / Emergency brake negative (-) input. This input is required for manual transmis

sion/reservation and turbo-timer mode. The proper wire will provide a (-) trigger when parking / emer

gency brake is set.

Pin 5 Red/Black [POC 2] – 2nd Starter 250mA negative (-) output. This output can be used to trigger the pre-

wired relay located on the main ignition harness.

Pin 6 Light Blue/White - Brake 12V positive (+) input. This input must be connected as it provides a shut

down for the remote start. The proper wire will test (+) 12V while the foot brake is pressed.

Pin 7 Green [POC 3] - 2nd Ignition 250mA negative (-) output. This output can be used to trigger the pre-

wired relay located on the main ignition harness.

Pin 6 Green/White – This is a dual-purpose wire that features selectable functionality thru the trunk/light

jumper on the control module. It is either a positive (+) parking light output or positive (+) trunk output.

This wire carries a 10 amp fuse.

Default - Parking light positive (+) output. The proper vehicle wire will test (+) 12V when the parking

light switch is in the on position.

Optional – Trunk release positive (+) output. The proper vehicle wire will test (+) 12V when the trunk

release is triggered.