Cm6000 install guide – Firstech, LLC. RF-2W900FM-5PT User Manual

Page 26

Advertising
background image

Copyright 2009 Firstech, LLC.

Page 26

CM6000

Install Guide

Alarm and Starter System

www.firstechonline.com | www.compustar.com

3-07 Siren Duration (Upon Alarm Trigger) - This option changes the time that the siren sounds during alarm

trigger. The available options are 30, 60, and 120 seconds. It will also sound chirps for 20 seconds as a

fourth option.

3-09

Horn Output When Alarm is Triggered - This changes the behavior of the white horn wire when the

alarm is triggered. With this setting you can change the wire to a constant (-) negative output for an ad

ditional siren.

3-10 Valet – This option changes valet modes.

Default 1: Key on/off five times or remote valet (I + III for 0.5 seconds) with key in the on position.

Option 2: Key on/off five times or remote valet (I+III for 0.5 seconds) – key does not need to be in the

on position.

Option 3: Secure valet: RPS Valet or remote valet (I+III for 0.5 seconds) – this option prevents the sys

tem from being put into valet via key on/off five times. To set up the RPS Valet feature, review the

“Placement and Use of Components” section.

3-11 Auxiliary settings – This option requires the installation of the optional Auxiliary settings module. The

Auxiliary settings adds five additional independent auxiliary outputs for a total of seven. With this op

tion turned on, auxiliary 2 becomes non functional and Aux 1 becomes the data wire for the Auxiliary

settings. Special Option Group 1 allows for independent timing of these outputs.

3-12 Passive Arming w/Auxiliary settings – The ability to activate/deactivate Passive Arming through the

remote is lost once Option 3-11 is turned on. This option allows the use of Passive Arming when using

the optional Auxiliary settings.

3-13 Defroster Temperature Control - When set to setting II, this option will disable the defroster output when

the temperature is above 32 F / 0 C. Setting I will activate the defroster regardless of the temperature.

3-14

Defroster Timing - Some vehicles need a pulse to activate the defroster, others will need a constant out

put to remain active, you can use this option to adjust the duration of the defroster output.

3-15 Soft Disarm - When a vehicle has a factory alarm, and the Firstech alarm is triggered, you may have

both alarms triggered at the same time. In the default setting, silencing the Firstech system will not send

the disarm pulse to the factory system, therefore requiring the user to first silence the Firstech system

and then unlock and disarm to silence the factory system. Setting II sends the disarm pulse when the

Firstech system is silenced.

Advertising