Pin 8 Violet/Black - Trunk negative (-) input. This is an optional input that will monitor when the vehicle’s

trunk has been opened. The proper wire will provide a (-) trigger while the trunk is open.

Pin 9 White/Black [POC 4] - 2nd Accessory 250mA negative (-) output. This output can be used to trigger the

pre-wired relay located on the main ignition harness.

Pin 10 Red/White - Door trigger input. This wire monitors negative (-) or positive (+) trigger door-pins. The

proper wire will provide a (-) trigger or a (+) trigger only when the doors are opened. You will need to

test the wire for proper polarity and set door dip switch on the control module for the corresponding

polarity. IMPORTANT: This wire is required for manual transmission remote starts.

Pin 11 Black [POC 5] – Status/Ground while running 250mA negative (-) output. This is an optional output that

will provide a negative (-) output before the ignition cranks and stay on throughout the remote start dura

tion. This wire is most commonly used to trigger bypass / transponder modules.

Pin 12 Brown/White - This is a dual-purpose wire that is selectable through Option 4-9 in the programming

able. Select the polarity through the glow/key jumper on the control module. It can be set to ac

cept either a positive (+) or negative (-) wait to start input / key sense.

Default – Glow plug positive (+) or negative (-) input. The proper vehicle wire will show a (+) or (-) trigger while the wait to

start light is on. This wire will delay the starter output momentarily to allow the glow plugs to warm up on vehicles equipped

with a diesel engine. You can adjust the delay with Option 2-3.

Optional – Key sense positive (+) or negative (-) input. The proper wire will show a (+) or (-) trigger only when the key is in

the ignition. The purpose of the key sense is to prevent the system from passively arming or setting reservation mode while

the key is still in the ignition.

Pin 13 Orange [POC 6] - Factory Arm 250mA negative (-) output. This is an optional output that will provide a

(-) pulse during lock, after crank and again after the ignition shuts down.

Pin 14 Pink - Slave/Closed Loop negative (-) input. This is a dual-purpose optional input that can be changed

through Option 4-10.

Default: Slave/Timer Start (-) input. This is most commonly used when adding a remote start to a fac

tory keyless entry system. You can adjust the number of pulses with Option 2-4.

Optional: Closed Loop (-) input. This wire acts as an instant trigger when separated from ground (-). It

is most commonly used to protect headlights or trailers.

Pin 15 Orange/White [POC 7] - Factory Disarm 250mA negative (-) output. This is an optional output that will

provide a (-) pulse during unlock and prior to the ignition turning on.

Pin 16 Yellow/Black - Engine sensing input. This wire is connected to the vehicles Tach or Alternator wire and

is required if you are not using the no tach sense setting. IMPORTANT: To change engine-sen

ing modes, you must change Option 2-10; Default requires a Tach input.