Troubleshooting

Unit does not turn on

Not plugged in.
Fuse blown or circuit breaker tripped.

Noise or vibration

Check that unit is level.

Unit is too warm

Check that doors are properly sealed.
To change the temperature, follow the steps in the

Operating Your Beverage Center

section of this manual.

LCD displays “PROBE ERROR – E”

This message is an ALARM MODE indication. The LCD displays

“PROBE ERROR”

on the left and

“E” in the middle when the thermostatic sensor has malfunctioned.

When this happens, the Beverage Center first stops working for 25 minutes, then

turns ON for 30 minutes and OFF for 20 minutes automatically and continuously.

Contact your authorized service facility for sensor replacement.

LCD displays “LOW TEMP”

This message is an ALARM MODE indication. The LCD displays

“LOW TEMP” on the

left and the letter

”L” in the middle. It indicates that the actual temperature in the

compartment is 32ºF or lower and that the magnet valve may not be functioning

properly and should be replaced. Contact your authorized service facility immediately.

LCD displays “HIGH TEMP”

This message is an ALARM MODE indication. The LCD displays

“HIGH TEMP” on the

left and the actual temperature reading in the middle. It indicates that the actual

temperature is much higher than your set temperature. Possible causes are:

• One or both of the doors might not be fully closed.
• The refrigerant may have leaked.
• The magnet valve may not be functioning properly and should be replaced.

If you are certain that the doors are not the cause of the problem, contact your

authorized service facility immediately.

LCD displays “H” or “L”

If either message is displayed in the Temperature Display zone in the middle of the

LCD, the ambient temperature around your appliance may be beyond the range of the

two-digit LCD, which can only display temperatures between -9ºF and 99ºF. If the

ambient temperature is below -9ºF, an

“L” will be displayed (but not “LOW TEMP”). If

the temperature is above 99ºF, an

“”H” will be displayed.

These occurrences are not malfunctions. Either move your unit to a more suitable

location or change the ambient temperature.

9