Fluke PN 3612805 User Manual

Page 8

Advertising
background image

373
Users Manual

4

Connect the common test lead before connecting the live test lead. When
disconnecting test leads, disconnect the live test lead first.

Do not work alone so assistance can be rendered in an emergency.

Use extreme caution when working around bare conductors or bus bars. Contact
with the conductor could result in electric shock.

Adhere to local and national safety codes. Individual protective equipment must
be used to prevent shock and arc blast injury where hazardous live conductors
are exposed.

Disconnect circuit power and discharge all high-voltage capacitors before you
measure resistance, continuity, or capacitance.

Do not measure current in circuits carrying more than 600 V or 600 A with the
Meter Jaw.

Never operate the Meter with the back cover removed or the case open.

W

Caution

To avoid possible damage to the Meter or to equipment under test:

Use the proper jacks, function, and range for the measurement application.

Clean the case and accessories with a damp cloth and mild detergents only.
Do not use abrasives or solvents. Make sure all water is removed before
use.

Advertising