1. PREFACE

This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 FEATURES

• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE

1.2 SPECIFICATIONS

MODELS

ITEMS

COOLING CAPACITY (BTU/h)

5,100

5,700

POWER SUPPLY (Phase, V, Hz)

1ø, 115V, 60HZ

INPUT (W)

470

530

OPERATING CURRENT (AMP.)

4.4

4.8

REFRIGERANT CONTROL

CAPILLARY TUBE

REFRIGERANT CHARGE (R-22)

330g (11.6 oz)

365g (12.9 oz)

INSIDE FAN

TURBO FAN

OUTSIDE FAN

PROPELLER FAN WITH SLINGER RING

AIR DISCHARGE

2-WAY (RIGHT AND LEFT)

CHASSIS

TOP-DOWN

PROTECTOR

TEMPERATURE CONTROL

THERMISTOR

FAN MOTOR

6 POLES, 21W

6 POLES, 27W

• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR

KP05A10

KP06A10