11 Troubleshooting

Symptom Cause

Action

Cascaded connections are done

Connect the dedicated AC
adapter to the master

The LOW POWER
LED is on

Lack of power supply

Connect the dedicated AC
adapter

The keyboard and mouse connections
on the PC are reversed

Match the port No.s

Hot Key Mode is not released

Press the [Enter] or [ESC] key

Not connected properly

Connect properly

Connection/cable is defective

Confirm the connector connection
Replace with a new cable.

The keyboard and
mouse do not
operate or operate
strangely

A non-supported keyboard or mouse is
connected

Replace with a supported
keyboard or mouse

Mouse not supported

Replace with a supported mouse

The scroll function or
button does not
operate

The specific mouse driver is not
installed

Install the specific mouse driver

Monitor or PC does not support PnP

Change to a supported
environment

The setting data is not saved

Refer to "Monitor Settings", and
set correctly

The PnP of the
monitor does not
function

Monitor side is connected with BNC
connector

Change to VGA connector

Poor screen display
(Faded images,
blurred characters,
etc.)

Connection/cable is defective

Confirm the connection
Replace with a new cable

Wrong resolution

Adjust the resolution or the
monitor settings

Window shifts or
does not display
when switching

Unsupported monitor, or cannot
synchronize

Replace with a supported monitor
(multisync)
Adjust the monitor

Hot Key is disabled

Initialize the Hot Keys

Cannot go into Hot
Key Mode

Wrong key or pressed wrongly

Refer to "Hot Key Mode", and
press correctly

Hot Key Mode is not on

Refer to "Hot Key Mode", and
press correctly

Auto Scan Mode
cannot be set

Wrong key

Press the number key (0)

Hot Key Mode is not on

Refer to "Hot Key Mode", and
press correctly

Switching cannot be
done by Keyboard

Wrong key

Refer to "SELECT Key", and
press correctly

The auto scan
switch cycle is
abnormal

The switch cycle has not been set
correctly
(The default value is 10 seconds)

Refer to "Auto Scan Mode", and
set correctly

Connection has been disrupted

Check the connections and restart

The switch is hung up

Press the reset switch

Operation stops after
a period of normal
operation

A problem has occurred at the PC

Correct the problem at the PC

The LED on the
device does not light
even after turning on
the host

The PC’s keyboard port’s power circuit
protection element has failed

Correct the problem at the PC

Non-Fujitsu switching device is
connected

Cascade with Fujitsu KVM switch

Cascaded
connections are not
recognized

A problem has occurred at the switch

Press the reset switch

14