3. MAINTENANCE, TROUBLESHOOTING

24

3.6

Troubleshooting

The table below provides basic trouble-
shooting procedures which the user may
follow to restore normal operation.

3.7

Diagnostics

If you feel your unit is not working properly,
conduct the diagnostic test to find the
problem. If you cannot restore normal opera-
tion, contact your dealer for advice.

1.

Press the MENU/ESC key to open the menu.

2. Use

S

or

T

to

choose Tests under System

and press the ENTER key.

Tests menu

3.

Use

S

or

T

to choose

Test and press the

ENTER key.

Test display

The ROM, SDRAM and NMEA port are
checked, with the results shown as OK or
NG (No Good). For any NG, request ser-
vice. (A special connector is required to
test the NMEA port. Nothing appears if no
connector is connected.)

4. The ovals and circles at the right side of the

test display are for checking the controls.
Checking key and TrackPad: Press each
key and the arrows on the TrackPad one
by one. A control's corresponding on-
screen oval "lights" in red if the control is
normal.

Troubleshooting table

If...

then check...

neither echo nor
fixed range scale
appears

• battery voltage.

• fuse.

• power supply.

• power cable.

no echo appears
but the fixed range
scale appears

• if display advance

speed is not set to
"Stop."

• transducer plug.

• transducer cable.

echo appears but
no zero line

• if range shifting is set

to "0."

• if zero line rejection is

off.

sensitivity is low

• gain setting.

• if air bubbles or marine

life is not clinging to
the transducer face.

• if sediments are not

present in the water.

• if the bottom is too soft

to return an echo.

there is extreme
interference or
noise

• if the transducer is too

close to the engine.

• if the unit is properly

grounded.

• if other echo sounders

of the same frequency
as own are being oper-
ated nearby.

the speed/water
temperature
readout is unreal-
istic or not present

• sensor plug.

the position
readout is unreal-
istic or not present

• the connection

between sounder and
navigator.

• navigator.

Tests

S

/

T

/

W

/

X

: Select

[ENTER] : Enter
[MENU] : Back

Test
LCD Test

ROM : OK
SDRAM : OK
NMEA :

Temp : -9.5

°

F

Speed : 10.0 kt

Power : 12.4 V

CPU Program No. : 0252346-XX.XX**
FPGA Program No. : 0252348-XX.XX
Push [MENU] 3 times to exit.

Water
temperature*,
Speed*

Battery
Voltage*

Color Bar

5.0

DUAL

}

Indication of
GAIN knob

Indication of
MODE knob

*: Updated every second.
XX: Program version number
**: FCV-620: 0252346-XX.XX
FCV-585: 0252347-XX.XX

ECHO : 4281