8 wiring – Furuno FCV-620 User Manual

Page 44

Advertising
background image

4. INSTALLATION

35

Thru-hull mount water temperature
sensor T-02MSB, T-03MSB

• Select a suitable mounting location consid-

ering the following points:

• Select a mid boat flat position. The sensor

does not have to be installed perfectly per-
pendicular; however, the location should
not be such that the transducer may be
damaged when the boat is dry-docked.

• Locate away from equipment which gives

off heat.

• Locate away from drain pipes.

• Select a location where vibration is min-

imal.

Procedure for mounting T-02MSB

1. Drill a hole of 21 mm in diameter in the

mounting location.

2. Pass the sensor cable through the hole.
3. Pass gasket, washer and locknut onto

cable in that order.

4. Coat the sensor flange with high quality

sealant and then fasten the sensor with the
locknut. (Torque: max. 59N m)

5. Launch the boat to check for water leakage

around the sensor.

Mounting T-02MSB

Procedure for mounting T-03MSB

1. Drill a hole of 25 mm in diameter in the

mounting location.

2. Coat holder guide with high quality sealant,

and pass gasket, washer and locknut onto
holder guide in that order and then tighten
the locknut.

3. Set the sensor holder to the holder guide

from inside the boat and then tighten the
locknut.

4. Launch the boat to check for water leakage

around the sensor.

Mounting T-03MSB

4.8

Wiring

Connect the power/data cable assy KON-
004-02M (2 m, supplied)

to the 12-24 VDC/

NMEA port, and the transducer cable to the
XDR port. Refer to the interconnection dia-
gram to connect cables. Leave slack in cables
to facilitate checking and maintenance.

Note1: Attach the MJ cable cap (supplied) to
the transducer cable to protect the connector
when the display unit is removed.

Note2: Cut unused cores and tape them.

Note3: Connector of cable edge breaks
easily. Be careful when connecting or discon-
necting the connector.

Note4: The fuse holder contains a spring
which fixes the fuse. To prevent detachment
of the spring, which would cause loss of
power, tie the line as shown on the next page.

.

Sensor
cable

Locknut

Coat with
sealant.

φ

21 mm

Washer
Gasket

Plate thick-
ness within
25 mm

Coat with
sealant.

φ

25 mm

Locknut

Locknut

Washer

Gasket

Holder Guide

Sensor Holder

Advertising
This manual is related to the following products: