Furuno – Furuno FCV-620 User Manual

Page 51

Advertising
background image

FURUNO

FCV-620/585

SP - 2

E2374S01D-M

3. INTERFACE

3.1

Input Data Sentences

IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0)

Order of priority

Latitude/Longitude:

GGA>RMC>RMA>GLL

Course (true): VTG>RMC>RMA

Course (magnetic): VTG

Ground speed: VTG>RMC>RMA

Water speed: VHW

Distance to waypoint: BWC>RMB

Bearing to waypoint (true): BWC>RMB

Bearing to waypoint (magnetic): BWC

Heading (true): HDT>VHW

Heading (magnetic): HDG>VHW

Cross track error: XTE>RMB

Atmospheric pressure: MDA

Water temperature: MTW

Wind speed and angle (true/apparent): MWV

3.2

Output Data Sentences IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0), interval: 2 s

DBT, DPT, MTW*, VHW*, TLL* by key operating

*: External data required

4. POWER

SUPPLY

4.1

FCV-620

12-24 VDC: 0.8-0.4 A

4.2

FCV-585

12-24 VDC: 1.0-0.5 A

5. ENVIRONMENTAL

CONDITION

5.1

Ambient Temperature

-15 °C to +50 °C

5.2

Relative Humidity

93 % at 40 °C

5.3 Waterproofing

and

IP55

Dust Proofing

(IEC60529)

5.4 Vibration

● 2-5 Hz and up to 13.2 Hz with an excursion of ±1 mm ±10 %

(7

m/s

2

maximum acceleration at 13.2 Hz)

● 13.2-100 Hz with a constant maximum acceleration of 7 m/s

2

6. CHASSIS

COLOR

6.1

Display Unit

Chassis: N-2.5

Bracket: N-1.75

Advertising