Discontinued, Fbr12 series, Specifications – FUJITSU FBR12 User Manual

Page 3

Advertising
background image

3

FBR12 SERIES

DISCONTINUED

(2002)

Item

High Sensitive Type

Standard (Gold-overlay silver-nickel) -P type (Gold-overlay silver-palladium)

Contact

Arrangement

2 form C (DPDT)

Material

Gold-overlay silver-nickel

Gold-overlay silver-palladium

Style

Bifurcated

Resistance (initial)

Maximum 100 m

(at 0.1 A 6 VDC)

Rating (resistive)

0.3 A 125 VAC or 1 A 30 VDC

Maximum Carrying Current

2 A (at 20

°

C)

Maximum Switching Power

62.5 VA or 30 W

Max. Switching Voltage*

1

250 VAC or 220 VDC

Maximum Switching Current

2 A

Minimum Switching Load*

2

10m VDC - 10

µ

A

Capacitance

Approximately 1.0 pF (between open contacts, adjacent contacts )

(at 10 kHz) Approximately1.0 pF (between coil and contacts)

Coil

Nominal power (at 20

°

C)

Approximately 50mW

Operate power (at 20

°

C)

Approximately 40m W

Operating Temperature

–40

°

C to +70

°

C (no frost) (refer to the CHARACTERISTIC DATA)

Operating Humidity

45 to 85%RH

Time Value

Operate (at nominal voltage)

Maximum 5 msec.

Release (at nominal voltage)

Maximum 5 msec.

Insulation

Resistance (initial)

Minimum 1000 M

(at 500 VDC)

Dielectric between open contacts

750 VAC

Strength

adjacent contacts

1 minute

between coil and contacts

1,500 VAC 1 minutes

Surge between open

1,500 V

Strength contacts,

10

×

700

µ

s

adjacent contacts

between coil and contacts

2,500 V
2

×

10

µ

s

Life

Mechanical

1 x 10

8

operations minimum

Electrical DC

2

×

10

5

operations minimum 5

×

10

5

operations minimum

(at contact rating)

AC

1

×

10

5

operations minimum

200

×

10

3

operations minimum

Other

Vibration Misoperation

10 to 55 Hz (double amplitude of 3.3` mm)

Resistance

Endurance

10 to 55 Hz (double amplitude of 5.0 mm)

Shock

Misoperation

500 m/s

2

(11

±

1

ms)

Resistance

Endurance

1,000 m/s

2

( 6

±

1

ms)

Weight

Approx. 1.9 g

SPECIFICATIONS

*

1

If the switching voltage exceeds the rated contact voltage, reduce the current. The current values vary according to the

type of load.

*

2

Values when switching a resistive load at normal room temperature and humidity and in a clean environment.

The minimum switching load varies with the switching frequency and operation environment.

Advertising