3.2 System Menu 1

DEPTH UNIT: Selects unit of depth

measurement among meters, feet, or fathoms.

Default setting is meters.

If "ft" or "fa" is selected, the depth unit is shown

in red characters.

SPEED UNIT: Selects unit of speed

measurement among knots, statute miles per

hour, or kilometers per hour. Default setting is

knots. Requires speed data, from external

device.

COURSE: Selects heading reference; true or

magnetic. Default setting is TRUE.

BOTTOM LOST: Turns on or off the bottom loss

warning. “ALARM” sounds the alarm if the

bottom signal is not detected. Default setting is

“ALARM” (alarm is enabled).

GPS ALARM: The audible alarm may be

released when the position-fixing mode is

switched from DGPS to GPS and vice versa.

Default setting is “ALARM” (alarm is enabled).

Choose “OFF” if you do not need to be alerted

with the audible alarm when the position-fixing

mode is switched.

INTERFACE: Selects I/O signal format between

the FE-700 and external equipment; IEC format

“1:95” (1995 version) or “1:98” (1998 version), or

NMEA format. Default setting is IEC “1:98”.

When selecting the “1:98”, DPT has max. range

in use (See page 24).

Output Input

IEC 61162-1

DPT

RMA, RMC

GLL, VTG

ZDA, GGA

NMEA 0183

DBT (Ver.1.5)

DBS (Ver.1.5)

DPT (Ver.2.0)

RMA, RMC

GLL, VTG

ZDA, GGA

ALARM SOUND: Selects audio alarm sound

among 1, 2 or 3. Default setting is 1.

1: Continuous sound

2: Intermittent sound; 0.5 s on and 0.5 s off.

3: Intermittent sound; 1 s on and 1 s off.

OS DATA: Selects own ship data display mode;

DATA 1 or DATA 2. DATA1 is the default setting.

If a navigation device is not connected to the

FE-700, select DATA 2.

LANGUAGE: Currently English is only available.

3.3 System Menu 2

TIME ADJUST: Selects internal clock or external

clock (UTC clock). Default setting is INTERNAL.

For INTERNAL, set current day, month, year,

hour, minute and second with [+], [-], [▼] or [▲]

key. The setting clock appears and it counts

upward.

SYSTEM MENU 2

MENU SELECT 1 2 3
TIME ADJUST

INTERNAL EXTERNAL

DAY

1

MONTH

JAN

YEAR

2001 (

2100)

HOUR

0 (0

23)

MINUTE

0 (0

59)

SECOND

0 (0

59)

01 JAN 2001 00:00:00


▼▲: To select item
- +: To set option

Select other mode to exit.

If EXTERNAL is selected, the screen changes

as follows.

SYSTEM MENU 2

MENU SELECT 1 2 3
TIME ADJUST

INTERNAL EXTERNAL

TIME DIFFERENCE AUTO MANUAL

0:22:40

▼▲: To select item
- +: To set option
Select other mode to exit.

TIME DIFFERENCE: Selects auto (UTC) or

manual. Auto uses the time difference in ZDA

(IEC 61162-1). In manual, it is necessary to

enter the time difference in hours and minutes.