5.2.4 Alarm

You can set turn alarm on or off. In the ON mode,

if the main display unit activates the alarm, the

FE-720 also.

1. Press the MENU key to display main menu.

2. Press [▲] or [▼] to select ALARM.

3. Press the ENT key. The following window

appears.

ON

OFF

4. Press [▲] or [▼] to select appropriate option.

The default is ON.

5. Press the ENT key to set.

6. Press the MENU key to finish.

If the alarm sounds, press any key to silence it.

5.3 Diagnosis

The diagnostic test checks ROM, RAM, keys and

LCD of the FE-720.

1.

Press the MENU key to display main menu.

2.

Press [▲] or [▼] to select TEST.

3.

Press the ENT key. The following window

appears.

TEST START?

(STOP : PWR OFF)

ARE YOU SURE?

YES NO

4.

With YES selected, press the ENT key to

start the test. The equipment tests the ROM

and RAM, displaying the results as OK or

NG (No Good). If NG appears, contact your

dealer for advice.

TEST

ROM : OK
RAM : OK

PUSH KEY
(STOP: PWR OFF)
CNT: 001 65-5-0100-003

5.

After "PUSH KEY" is displayed, press each

key one by one. The name of the key

pressed momentarily appears if the key is

functioning properly.

The display shows the following message to

inform you that the program is now going to

check the LCD.

<LCD CHECK>

ALL ON 2 SEC

ALL OFF 3 SEC

The whole display brightens for 2 seconds then

turns off for 3 seconds. Test repeats. CNT, which

is number of times the test has been

consecutively executed, is counted up.

6.

To stop the test, turn off the power.

5.4 Factory Setting

You can restore default settings to start operation

anew. Press the POWER switch while pressing

[▲]. The message "RESET BACKUP DATA!"

appears. After a while, all default settings are

restored and the depth indication appears.