5 troubleshooting – Furuno FE-700 User Manual

Page 30

Advertising
background image

20

6.5 Troubleshooting

The table below provides simple troubleshooting procedures which you may follow to restore normal
operation. If you cannot restore normal operation, contact your dealer.

SYMPTOM PROBABLE

CAUSES

REMEDY

Low power supply

Check the supply voltage.

Fuse blown

Replace the fuse.

No picture; no reading
measure

Power cable damaged

Check the cable and repair.

Transducer cable damaged

Repair the cable.

Transducer cable connection
loosened

Tighten the connections.

No echo sounding picture

Transmitter not working

Make sure the maximum output power is
selected. (See section 3.2 System Menu 1.)

Low sensitivity

Increase the Gain by turning the GAIN control
clockwise.

Low reflectivity from seabed

Suspect muddy seabed.

Irregular display

Marine life on transducer

Remove marine life from the transducer when
dry docked.

Out of range

Check the range scale setting.

Loss of seabed display

Air bubbles caused by going
astern or running over other
ship wakes

This is normal, it is not a sign of equipment
trouble.

Wrong installation place of
transducer

Find cause of noise. Relocate the transducer if
noise persists.

Heavy noise

Other echo sounders nearby

If more than one echo sounder is working on
the ship, there is no ideal measure to cure the
problem.

Aeration in near surface area

Not an equipment problem.

Surface noise

Rough weather

Not an equipment problem.

Advertising