FUJITSU ServerView V6.00 User Manual
Page 127

ServerView Event Manager
127
Trap overview
fanFailureTrap
5
The fan in the specified
location has failed. Replace
fan.
major
fanInformationTrap
6
The fan in the specified
location was recovered.
informational
lunFailureTrap
16
The LUN has failed and is
off-line. Possible cause is
too many failed disk drives
that make up the LUN, the
OS can no longer
communicate with the LUN
for other reasons.
critical
lunInformationTrap
19
A LUN has become optimal
due to successful
completion of the
reconstruction process.
informational
lunReconstructTrap
17
The LUN has started the
reconstruction process but
is available for normal use.
Possible causes are an
available disk drive was
created as a spare to be
inserted into the set, an
existing spare was
automatically added to the
set for reconstruction upon
failure of a member disk
device.
minor
lunReducedTrap
18
A LUN has become
degraded due to a member
disk device failure. Replace
the failed disk device; add a
spare to the system to
cause a reconstruct.
major
Trap name
ID
Meaning
Error class
Table 38: PXRE traps