Alarm configuration example

4.12

Alarm configuration example

This section explains a typical example of alarm configuration.

Purpose

When an event whose severity is critical occurs on the

ALARMTEST

server, a

mail is sent to the administrator (

[email protected]

).

Requirements

–

ServerView agent is running on the server, and the server is registered as a
management target in ServerView Operations Manager on the same
network.

–

Test traps from the ServerView agent to ServerView Operations Manager
are functioning normally.

–

ServerView Operations Manager can access the SMTP server
(111.222.3.20) while it is in operation.

Setting procedure

Ê

Perform one of the following operations.

–

When operating from the ServerView Operations Manager start window:

Click

Alarm Configuration

.

–

When operating from the individual function windows:

Click

Event Management – Alarm Configuration

in the menu bar at the top

of the window.

The

Manage Alarm Rules

window opens.

Ê

Click

Add

.

The

New Name

dialog box opens.

Ê

Enter e.g.

CriticalMail

in the

New Name

dialog box and click

OK

.

Ê

Click

Apply

, then click

Next

.

The

Assign Servers

window opens.

Ê

Select the

ALARMTEST

server in the server list, and click the > button.