Owner’s manual, Operating appliance, Continued – FMI FVTR24 User Manual

Page 13: Gas shutoff valve operation, Curing logs, Operating instructions for ga9003

Advertising
background image

13

901846

OWNER’S MANUAL

GAS SHUTOFF

VALVE OPERATION

Flame Adjustment

Adjust the flame ON/OFF by turning the
gas shutoff valve counterclockwise

to open or clockwise

to

close, as necessary.

Shutting Off Appliance

Turn gas shutoff valve clockwise
to the OFF position.

During the 2-3 hour appliance break-in
period, you may detect an odor from the
appliance as the various paints and com-
pounds used in the manufacturing of this
log set cure. This is a normal and tempo-
rary situation that is not cause for alarm.
However, you may want to provide extra
ventilation to the room during this time.
To ensure proper curing of the logs:
• Ignite a 2" flame and maintain it for 1

hour.

• Burn the logs in consecutive 1 hour pe-

riods raising the flame an additional
2" to full flame height for a total of
three hours.

CURING LOGS

Note:

Operation instructions for GA9103

Remote Ready Valve/Pilot Kit will be
included with the Kit.

1.

STOP! Read the safety information,
page 12.

2.

Make sure equipment shutoff valve
is fully open.

3.

Press in and turn control knob clock-
wise

to the OFF position.

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas around log set
and near floor. If you smell gas,
STOP! See Safety information
, page 2
and Air For Combustion And Ventila-
tion
, pages 4 through 6. If you don’t
smell gas, go to the next step.

5.

Turn control knob counterclockwise

to the PILOT position and

press in. Keep control knob pressed
in for five (5) seconds.

Note:

You may be running this log

set for the first time after hooking up
to gas supply. If so, the control knob
may need to be pressed in for 30 sec-
onds. This will allow air to bleed from
the gas system.
• If control knob does not pop up

when released, contact a qualified
service person or gas supplier for
repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the rear of the front burner. If
needed, keep pressing ignitor button
until pilot lights.

Note:

If pilot does not stay lit, con-

tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

to the ON position. Burner

should light. If burner does not light,
call a qualified service person.

OPERATING

INSTRUCTIONS FOR

GA9003

Ignitor

Control Knob

Pilot

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

ON

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

FROM "PILOT" POSITION

SLIGHT PUSH TO

TURN OFF

PULL PUSH

ON

OFF

On

Off

OFF

OFF

Pilot

Thermo-
couple

Figure 22 - Ignitor and Control Knob

Figure 23 - Thermocouple and Pilot

OPERATING
APPLIANCE

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Appliance

1.

Turn control knob clockwise
to the PILOT position.

2.

Press in and turn control clockwise

to the OFF position.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise

to

the PILOT position.

Advertising