Vented natural gas logs, Troubleshooting, Continued – FMI FVTR24 User Manual

Page 16

Advertising
background image

16

901846

VENTED NATURAL GAS LOGS

TROUBLESHOOTING

Continued

www.desatech.com

WARNING: If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your

building.

• Immediately call your gas supplier from a neighbor’s phone. Follow the

gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

POSSIBLE CAUSE

1. Metal expanding while heating or con-

tracting while cooling

1. Log Set burning vapors from paint, hair

spray, glues, cleaners, chemicals, new
carpet, etc. (See

IMPORTANT

state-

ment above)

2. Gas leak.

See Warning statement at

top of page

1. Gas leak.

See Warning statement at

top of page

2. Control valve defective

1. Gas leak.

See Warning statement at

top of page

OBSERVED PROBLEM

Log Set produces a clicking/ticking noise
just after burner is lit or shut off

Log Set produces unwanted odors

Gas odor even when control knob is in OFF
position

Gas odor during combustion

REMEDY

1. This is common with most log sets. If

noise is excessive, contact qualified ser-
vice person

1. Open flue to maximum. Stop using odor

causing products while log set is running

2. Locate and correct all leaks (see Check-

ing Gas Connections, pages 8 and 9)

1. Locate and correct all leaks (see Check-

ing Gas Connections, pages 8 and 9)

2. Replace control valve

2. Locate and correct all leaks (see Check-

ing Gas Connections, pages 8 and 9)

IMPORTANT:

Operating log set where impurities in air exist may create odors. Cleaning

supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These odors
will disappear over time.