Maintained mode – Furman Sound PS-PRO HT User Manual

Page 5

Advertising
background image

P S - P R O H T - P O W E R CO N D I T I O N E R / S E Q U E N C E R

switches and push-on/push-off button switches,

(including the Furman RS-1 key lock switch),

stay open until switched, and then remain closed

until switched again. Momentary switches,

usually push-button types like the Furman RS-2

(which also provides a locking key switch), are

normally open and stay closed only as long as

the button is pressed.
Maintained switches are generally most

convenient when there is only one remote

location. When more than one location is required,

momentary switches offer the advantage of

a turn-on or turn-off sequence which may be

started from any location.
For integrating the PS-PRO HT into computer

control/touch screen systems use “momentary

mode.”
The PS-PRO HT main circuit board has 5 pairs

of terminals labeled as:
JMP1 (MAINT ON), when the REM and +12V

terminals are tied together, the PS-PRO will

sequence OFF.
JMP2 (MOMENTARY), when the REM and +12V

terminals are momentary tied together, the PS-

PRO will sequence ON or OFF.
JMP3 (MAINT OFF), when the REM and +12V

terminals are tied together, the PS-PRO will

sequence ON.
JMP4 (REM TO GND = ON), when the REM and

GND terminals are tied together, the PS-PRO

HT will sequence ON (Note: JMP1 must have a

jumper installed).
JMP5 spare jumper holder.
PS-PRO HT units come factory-set for maintained

operation (jumper is installed on JMP3). They

may be easily converted to other operating

modes by moving jumper plug/plugs on the

PS-PRO HT’s circuit board. To do this, first

disconnect the unit from AC power. Remove

the four screws that secure the top cover and

one screw from the front panel. Just install the

jumper plugs to the desired mode of operation.

Reattach the top cover.

Maintained Mode

There are 3 maintained modes of operation:

REM to +12V = OFF (jumper plug installed on

JMP1, MAINT ON)
The connection of the REM terminal to the +12V

terminal initiates an OFF sequence. Use this

setting when you want to use the RS-1 as a

remote controller.

(Continued on page 7)
(Continued from page 4)
Disconnecting initiates an ON sequence. If the

cable run is long, it is recommended that the

REM wire be tied to the PS-PRO HT’s GND

terminal during ON operation rather than leaving

it floating. This will require the use of a third

conductor and a double-throw switch.
REM to +12V = ON (jumper plug installed on

JMP3, MAINT OFF) Defaut Setting
The connection of the REM terminal to the +12V

terminal initiates an ON sequence. Disconnecting

initiates an OFF sequence. If the cable run is

long, it is recommended that the REM wire be

tied to the PS-PRO HT’s GND terminal during

OFF operation rather than leaving it floating.
REM to GND = ON (jumper plugs installed on

JMP1 and JMP4)

4

Advertising