Effects of lightning, Status terminal – Furman Sound PS-PRO HT User Manual

Page 9

Advertising
background image

P S - P R O H T - P O W E R CO N D I T I O N E R / S E Q U E N C E R

other units.
The STATUS lines work the same in either

mode. Each reflects the true state of the unit’s

outlets and is affected by both the “memorized”

state and by the key lock switch. A separate

LED must be used to indicate the status of each

PS-PRO HT.

To address the unusual (hopefully rare) instance

when several PS-PRO HTs in parallel fall out of

sync, resulting in some units turning on and oth-

ers turning off when a remote button is pushed,

the remote signal line has a special feature:

Holding the REM line high for at least 4 seconds

will force all units to the OFF state, putting them

back in sync. This is the only way to re-sync units

other than disconnecting AC power to all units.

Remember — turning any key lock switch to OFF

does not affect the stored state, even though it

will temporarily turn the output of that unit off. If

it is turned back to REM, the PS-PRO HT will

sequence back to ON because the stored state

is still ON.

The above covers the case of multiple units in

parallel (all sequences initiate simultaneously).
See “AC Relay Accessory PS-REL” below for a

discussion of wiring multiple units in series.

STATUS Terminal

The STATUS terminal is an output that may be

used to illuminate an LED at the remote location

indicating that the power is available at the PS-

PRO HT’s outlets. If it is high (+5V), the unit is ON

(or at least in the process of sequencing ON); if

low, the unit is OFF (or sequencing OFF). Simply

connect the indicator LED between STATUS

and ground (do not use a series resistor). If the

LED does not light when the switch is in the ON

position check the polarity and reverse the LED

leads if needed.

Effects of Lightning

8

Lightning is a natural phenomenon of over-

whelming force that represents the most dif-

ficult circumstance faced by a power protection

product. The degree of protection a PS-PRO

HT can offer depends on the intensity of the

strike. If lightning strikes a distant power line

and causes a relatively small disturbance to

reach your location, the spike suppressors in

the PS-PRO HT will absorb the excess voltage

invisibly and harmlessly. However, if lightning

strikes the actual building where the PS-PRO HT

is installed (or somewhere very nearby), some

damage may be unavoidable due to the ex-

tremely high voltage and current present. If this

does occur, most likely damage will be limited to

the PS-PRO HT itself and will affect only certain

spike suppression components (called varistors

or MOV’s.) In this “suicide” mode, the PS-PRO

HT may sustain minor damage but generally

will protect all equipment plugged into it from

much more serious and costly damage as long

as that equipment is properly grounded. Proper

grounding requires the use of three-prong AC

cords, and that the building’s outlets are actually

grounded to earth as specified by the National

Electrical Code.
Any PS-PRO HT known to have taken a direct

lightning hit should be checked by a qualified

technician or the Furman factory to determine

of the MOV’s need replacement. (If the PS-PRO

HT’s PROTECTION OK indicator is not lit, there

is definitely some damage. Some spike suppres-

sion capability may still be available by MOV

Bank #2, but there is no guarantee of this.)
For optimum protection, you should not rely ex-

clusively on the PS-PRO HT to protect against

a direct lightning hit. The first line of defense

against lightning should be a lightning arrestor

installed on your building’s electrical service

entrance. If your building does not have one,

contact your local power company or an electri-

cal contractor to have one installed.

Advertising