Rear panel – Furman Sound PS-PRO II User Manual

Page 7

Advertising
background image

P S - P R O I I - P O W E R C O N D I T I O N E R / S E q u E N C E R

BNC Connector

for rear light

(models GN-I or

GN-LED)

POWER STaTuS (DElaY) lEDs: One green

LED is provided for each of the three delay

stages. Each LED lights when power is applied

to its corresponding duplex outlet on the rear

panel. All three LEDs then remain lit until power

is removed. During the power-down delay cycle,

each LED goes off as power to its correspond-

ing outlet is removed. In addition, the Delay 1

LED flashes if a remote switch (or the stored

state) is OFF.

uNSWITCHED OuTlET: This convenient outlet

provides power at all times when the PS-PRO II

is plugged in and operating under normal power

conditions.

CIRCuIT BREaKER: The overall capacity of

the PS-PRO II is 20 amps. Should the com-

bined steady-state current drawn by all devices

plugged into the unit at any time exceed 20

amps, the circuit breaker will trip, cutting off

power to your rack. If this occurs, reduce the

load by unplugging one or more units from the

PS-PRO II, and reset it. you can reset the circuit

breaker by simply pressing the button, which

pops out when tripped. However, because it

is a thermal type, you may have to wait a few

moments after it trips for it to cool down before

it will allow you to reset it.

ON/REm/OFF SWITCH: When turned to the

ON position, this key lock switch initiates an

ON sequence, applying power to the PS-PRO

II’s switched outlets. When turned to the OFF

position, it begins an OFF sequence. In the

REM position, the PS-PRO II will accept on/off

commands from a remote switch or switches that

may be connected to the rear panel terminals.
UNSWITCHED OUTLETS: The PS-PRO II rear

panel provides clean, filtered power to this pair

of unswitched outlets, adjacent to the power

cord.
SWITCHED (DELAyED) OUTLETS: The

PS-PRO II rear panel provides three pairs of

switched outlets, widely spaced to allow use of

equipment with plug- in (wall wart) transformers.

These switched outlet pairs are labeled Delay 1,

Delay 2 and Delay 3. After the front panel switch

is thrown to ON, Delay 1 outlets receive power

instantly, Delay 2 outlets receive power 1-30

seconds later and Delay 3 outlets receive power

1-30 seconds after Delay 2 outlets are powered.

When thrown to OFF, the sequence is reversed,

with Delay 3 losing power instantly, Delay 2 out-

lets losing power 1-30 seconds later and Delay

1 outlets losing power 1-30 seconds after Delay

2 outlets are shut down. The delay intervals

may be altered with the screwdriver-adjustable

Delay Adjust control on the front panel.
TERMINAL STRIP: Allows one or more switches

to be connected to turn the PS-PRO II on and

off from a remote location. Two, and sometimes

three, wires are needed to install a remote

switch (see “Maintained Mode”, page 6.) If a

four-conductor cable is used, an LED may be

installed at the remote end to indicate that the
power is on.

REaR PaNEl

6

Advertising