6 touch panel control driver api, Touch panel control driver api – FUJITSU FMB AN706 User Manual

Page 63

Advertising
background image

AN706-00040-2v0-E

62

7.2.4.6 Touch Panel Control Driver API

Function

STATUS TOUCH_Init(void)

Overview

Initialization function for touch panel control driver

Invoked before entering the main loop (see

“7.2.8.1 Main Processing

Function

).

Parameter None

Return

value

Processing results

TOUCH_RET_OK

Normal completion

TOUCH_RET_ILLEGAL_ERROR Timer setting failure

Function

STATUS TOUCH_GetAreaStatus(uint16_t* Status)

Overview

Touch panel area status acquisition function

Parameter Status

Pointer to area status acquisition information storage destination

If successful, area (see Figure 47) status (touch by 1) is written by bit.

bit0

Area 1

bit1

Area 2

bit2

Area 3

bit3

Area 4

bit4

Area 5

bit5

Area 6

bit6

Area 7

bit7

Area 8

bit8

Area 9

Return

value

Processing results

TOUCH_RET_OK

Normal completion

TOUCH_RET_INVALID_PARAMETER

Parameter error