Venting installation – FMI (V)3612ST User Manual

Page 7

Advertising
background image

www.fmiproducts.com

115603-01D

7

Figure 14 - Pipe Connection

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

V3612ST

See-Through

Fireplace

52

3

/

4

"

48-12DM

48-12TM

Flue Pipe

46

5

/

8

"

36-12DM

48-12TM

Flue Pipe

34

5

/

8

"

24-12DM

48-12TM

Flue Pipe

22

5

/

8

"

18-12DM

48-12TM

Flue Pipe

16

5

/

8

"

12-12DM

48-12TM

Flue Pipe

10

5

/

8

"

STL-12D

Chase Style

Termination

1" to 12"

RLT-12D

Round Top

Termination

7"

Hemmed

End

12 3/8"

Stainless

Inner Pipe

15" Galvanized

Outer Pipe

PIPE INSTALLATION

The pipe sections must be assembled inde-

pendently as the chimney is installed. When

connecting chimney directly to the fireplace,

the inner flue pipe section must be installed first

with the lanced side up. The outer pipe section

can then be installed over the flue pipe section

with the hemmed end up. Press down on each

pipe section until the lances securely engage

the hem on the fireplace starter. The wire will

assure the proper spacing between the inner

and outer pipe sections.

Continue to assemble chimney sections as

outlined above, making sure that both the

inner and outer pipe sections are locked to-

gether. When installing double wall snap-lock

chimney together, it is important to assure the

joint between the chimney sections is locked.

Check by pulling chimney upward after lock-

ing. The chimney will not come apart if prop-

erly locked. It is not necessary to add screws

to keep the chimney together (exception, see

Figure 17, page 8).

WARNING: The opening in the

collar around the chimney at the

top of the fireplace must not be

obstructed. Never use blown insula-

tion to fill the chimney enclosure.

Figure 13 - Outside Air Kit Installation

Secure to Collars with

Duct Tape or Screws

Air Inlet

Location

Must Allow

For Bushes

or Snow

Vent Hood

Required for

Wall Installation

Air Inlet

Termination

Vented Crawl Space

(Check Local Codes

Before Installing in a

Vented Crawl Space)

CHIMNEY PIPE

The FMI PRODUCTS, LLC chimney is a

snap-lock, double-wall pipe. It consists of a

stainless steel inner flue pipe(s), a galvanized

outer pipe and a wire spacer.
Each section of pipe comes in lengths of 12",

18" 36" and 48". The actual lineal gain for

each is measured after each section is fully

connected. Lineal gain is the actual measur-

able length of a part after two or more parts

are connected.

VenTing inSTallaTion

Continued

USING ELBOW OFFSETS AND

SUPPORTS

Chimney weight above offset rests on return

elbow. Straps must be securely nailed to raf-

ters or joists (see Figure 15, page 8).

To achieve desired offset, you may install

combinations of 12", 18", 36" and 48" length

of double wall pipe (see offset chart and

Figure 16, page 8).

The chimney support section is a 4" strap

and 12" length of pipe. A chimney support is

required every 30 feet above fireplace after a

straight chimney run or above a return elbow

after a straight chimney run (see Figure 17,

page 8). This support is designed to relieve

the extra weight load on fireplace and elbows

when high chimneys are installed.